Industrial Projects and Engineering Experience

Below is a selection of engineering projects CAEMAG has executed across industrial sectors in Uzbekistan and Central Asia. Each project reflects a real operational problem, an engineering-based solution, and a measurable outcome.
Client names are not disclosed by agreement. Industry, equipment type and project results are described as accurately as possible.
Project 1:

Ball Mill Drive System Modernization

  • Application:
    Grinding mill (ball mill) — ore processing facility, Uzbekistan
    Equipment:
    Planetary gearbox + electric motor (imported unit, manufacturer [to be confirmed])

Problem

  • Gearbox overheating under full production load
  • High vibration levels causing unplanned stops
  • Frequent emergency shutdowns — 3–4 times per month
  • Bearing wear accelerated by misalignment not corrected during original installation
  • Engineering Diagnosis

    Load analysis revealed the original gear ratio was selected incorrectly for the actual torque profile of the mill. Additionally, shaft alignment deviated by 0.4 mm — above acceptable tolerance for this class of equipment.
Solution
  • Full gearbox disassembly and defect inspection
  • Replacement of main bearings and gear set
  • Shaft realignment and coupling replacement
  • Load recalculation and gear ratio correction
  • Installation of temperature monitoring point
Result
  • Stable operation under full production load achieved
  • Unplanned stops eliminated for 8+ months after repair
  • Vibration levels reduced to within OEM specification
  • Client avoided full gearbox replacement — repair cost approximately 30% of new unit price
Project 2:

Conveyor Drive System Upgrade

  • Application:
    Ore transport conveyor — mining operation, Navoi region area
    Equipment:
    Helical-bevel gearbox + motor-reducer

Problem

  • Progressive gear wear causing conveyor speed instability
  • Incorrect gear ratio selection at original commissioning
  • Electric motor running in overload condition — thermal protection tripping regularly
  • Engineering Diagnosis

    System audit confirmed motor was operating at 118% of rated current during normal loading. Gear ratio was 12:1 where application required 16:1. This caused both motor overload and accelerated gear wear.
Solution
  • System audit and gear ratio recalculation
  • Replacement with correctly sized NORD motor-reducer unit
  • Installation of upgraded flexible coupling system
  • Motor protection relay recalibration
Result
  • Motor operating at 87% rated current — within normal range
  • Gear service interval extended from 6 weeks to 6+ months
  • Energy consumption reduced by approximately 11%
Project 3:

Crusher Drive Refurbishment

  • Application:
    Primary jaw crusher — quarry operation
    Equipment:
    Heavy-duty gearbox (Soviet-era unit, no spare parts available from original supplier)

Problem

  • Significant gear tooth damage on primary stage
  • Shaft misalignment causing progressive housing damage
  • Risk of catastrophic failure and extended production stop
  • Engineering Diagnosis

    Visual inspection and measurement revealed 2.1 mm shaft runout and 3 gear teeth with damage beyond self-healing tolerance. Continued operation would have resulted in full gear set destruction within estimated 2–4 weeks.
Solution
  • Full gearbox disassembly
  • Gear tooth restoration using welding and precision grinding
  • Shaft straightening and alignment correction
  • Housing crack repair and reinforcement
  • Full reassembly with new bearings and seals
Result
  • Equipment restored to service — estimated remaining service life 3–5 years
  • Avoided full unit replacement — estimated saving: significant, as equivalent unit not available domestically
  • 12 days for full repair vs. estimated 60–90 days for imported replacement procurement
Project 4:

Kiln Drive Gearbox Overhaul

  • Application:
    Rotary kiln drive — cement plant, Central Uzbekistan
    Equipment:
    Heavy-duty open gear reducer (Flender-type unit)

Problem

  • Increasing gear backlash and elevated noise level over 3-month period
  • Oil contamination — metallic particles detected in routine oil sample
  • Production management concerned about kiln stop risk
  • Engineering Diagnosis

    Oil particle analysis indicated secondary gear stage wear. Backlash measurement: 1.8mm — above the 0.8mm limit for this application. Main pinion showed pitting on 40% of tooth contact surface.
Solution
  • Gear inspection and refurbishment of contact surfaces
  • Full bearing replacement — both main stages
  • Lubrication system clean-out and reconfiguration
  • Pinion replacement from stock
  • Reassembly and load testing
Result
  • Backlash corrected to 0.6mm — within specification
  • Kiln operating without interruption for 14+ months post-repair
  • Oil sample metallic particle count reduced to baseline level
  • Scheduled overhaul interval established — annual inspection program agreed with client
Project 5:

Raw Mill Drive Power Optimization

  • Application:
    Raw material grinding mill — cement production
    Equipment:
    Gearbox + electric motor (SEW-Eurodrive motor-reducer unit)

Problem

  • Excessive energy consumption — 18% above design specification
  • Load imbalance between mill compartments
  • Motor operating at elevated temperature
  • Engineering Diagnosis

    Motor current logging over 72 hours confirmed consistent overload pattern correlated with material feed rate. Gearbox internal efficiency loss estimated at 4–6% due to worn bearing preload. Drive configuration suboptimal for actual material density profile.
Solution
  • Gearbox bearing replacement and preload adjustment
  • Motor and gearbox operational matching — control parameters revised
  • Feed rate optimization recommendations provided to process team
Result
  • Energy consumption reduced by approximately 14% within 30 days
  • Motor temperature reduced by 12°C under standard load
  • Drive efficiency confirmed by power factor measurement before/after
Project 6:

Reactor Agitator Drive Integration

  • Application:
    Chemical mixing reactor — process plant
    Equipment:
    Motor-reducer + flexible coupling

Problem

  • Unstable agitator rotation speed — product quality affected
  • Coupling failure every 6–8 weeks due to shaft misalignment
  • Vibration transmitted to reactor structure
  • Engineering Diagnosis

    Shaft alignment measurement: 0.7mm parallel offset — significantly exceeding the 0.1mm tolerance required for this coupling type at operating speed. Original coupling selection was rigid type — inappropriate for this drive configuration.
Solution
  • Replacement of rigid coupling with flexible jaw-type coupling
  • Precision shaft alignment using dial gauge method
  • Motor-reducer selection review — confirmed unit was correctly sized
  • Vibration isolation pad installation at motor mount
Result
  • Coupling service life increased from 6–8 weeks to 18+ months (last recorded before end of contract period)
  • Agitator speed stability improved — product quality issue resolved
  • Vibration at reactor structure reduced by measured 60%
Project 7:

Pump Station Drive Modernizatio

  • Application:
    Industrial fluid transfer pump station
    Equipment:
    Electric motor + gearbox + coupling

Problem

  • High vibration — vibration levels at 3× OEM alarm threshold
  • Coupling failure every 4–6 weeks
  • Motor overheating under peak flow conditions
  • Engineering Diagnosis

    Vibration spectrum analysis identified dominant frequency corresponding to 1× shaft speed — classic unbalance signature. Secondary peak at bearing pass frequency indicated bearing damage. Motor current analysis showed intermittent overload during pump cavitation events.
Solution
  • Dynamic balancing of pump impeller
  • Bearing replacement and shaft realignment
  • Coupling upgrade to accommodate angular and parallel misalignment
  • Motor protection threshold recalibration
Result
  • Vibration reduced from 3× to within OEM specification
  • Coupling replacement interval extended to 12+ months
  • No motor trips recorded in 6 months following repair
Project 8:

Pump Drive System Repair — Water Infrastructure

  • Application:
    Municipal water supply pump station — Central Asia region
    Equipment:
    Large-frame electric motor (Siemens SIMOTICS-type unit) + gearbox

Problem

  • Motor insulation degradation — insulation resistance below acceptable level
  • Gearbox oil leakage — seal failure across multiple positions
  • Vibration increase over 8-month period
  • Engineering Diagnosis

    Motor insulation testing: 2.4 MΩ at 500V — below the 10 MΩ minimum for this motor class. Gearbox seal failure traced to incorrect seal material for operating temperature range. Vibration source: bearing inner race fretting on output shaft.
Solution
  • Motor winding insulation restoration — vacuum impregnation process
  • All gearbox seals replaced — correct material grade specified
  • Output shaft bearing replacement and housing bore correction
  • System alignment verification
Result
  • Motor insulation resistance restored to 480 MΩ — fully operational
  • Gearbox oil leakage eliminated — zero leakage at 6-month inspection
  • Vibration at OEM baseline level
  • Pump station restored to full operational capacity
Project 9:

Conveyor Drive Upgrade — Food Processing

  • Application:
    Product transport conveyor — food processing facility
    Equipment:
    Motor-reducers (3 units on single line)

Problem

  • Inconsistent conveyor speed across line — synchronization issue
  • High wear rate on drive components — replacement every 3 months
  • Noise level above acceptable for food environment
  • Engineering Diagnosis

    Speed variation traced to inconsistent gear ratios across three motor-reducer units — units were from different production batches with 3.2% speed tolerance mismatch. Wear rate caused by repeated micro-shock loading from speed differential.
Solution
  • Replacement with matched set of NORD motor-reducers — verified same gear ratio across all three units
  • Hygienic design units selected — appropriate for food environment
  • Drive integration into existing conveyor frame without structural modification
Result
  • Conveyor speed synchronization achieved — product positioning accuracy restored
  • Drive component replacement interval extended from 3 months to 18+ months (manufacturer specification: 24 months)
  • Noise level reduced by 8 dB

What These Projects Demonstrate

Typical Equipment We Work With

  1. Planetary, helical and bevel-helical gearboxes — all power ranges
  2. Motor-reducers from major OEM brands
  3. Low and medium voltage industrial motors
  4. Industrial couplings and shaft systems
  5. Ball mill drives, conveyor systems, crusher drives, pump drives
Send your technical task — we will analyze your system and propose a solution.