Below is a selection of engineering projects CAEMAG has executed across industrial sectors in Uzbekistan and Central Asia. Each project reflects a real operational problem, an engineering-based solution, and a measurable outcome.
Client names are not disclosed by agreement. Industry, equipment type and project results are described as accurately as possible.
Planetary gearbox + electric motor (imported unit, manufacturer [to be confirmed])
Problem
Gearbox overheating under full production load
High vibration levels causing unplanned stops
Frequent emergency shutdowns — 3–4 times per month
Bearing wear accelerated by misalignment not corrected during original installation
Engineering Diagnosis
Load analysis revealed the original gear ratio was selected incorrectly for the actual torque profile of the mill. Additionally, shaft alignment deviated by 0.4 mm — above acceptable tolerance for this class of equipment.
Solution
Full gearbox disassembly and defect inspection
Replacement of main bearings and gear set
Shaft realignment and coupling replacement
Load recalculation and gear ratio correction
Installation of temperature monitoring point
Result
Stable operation under full production load achieved
Unplanned stops eliminated for 8+ months after repair
Vibration levels reduced to within OEM specification
Client avoided full gearbox replacement — repair cost approximately 30% of new unit price
Project 2:
Conveyor Drive System Upgrade
Application:
Ore transport conveyor — mining operation, Navoi region area
Incorrect gear ratio selection at original commissioning
Electric motor running in overload condition — thermal protection tripping regularly
Engineering Diagnosis
System audit confirmed motor was operating at 118% of rated current during normal loading. Gear ratio was 12:1 where application required 16:1. This caused both motor overload and accelerated gear wear.
Solution
System audit and gear ratio recalculation
Replacement with correctly sized NORD motor-reducer unit
Installation of upgraded flexible coupling system
Motor protection relay recalibration
Result
Motor operating at 87% rated current — within normal range
Gear service interval extended from 6 weeks to 6+ months
Energy consumption reduced by approximately 11%
Project 3:
Crusher Drive Refurbishment
Application:
Primary jaw crusher — quarry operation
Equipment:
Heavy-duty gearbox (Soviet-era unit, no spare parts available from original supplier)
Risk of catastrophic failure and extended production stop
Engineering Diagnosis
Visual inspection and measurement revealed 2.1 mm shaft runout and 3 gear teeth with damage beyond self-healing tolerance. Continued operation would have resulted in full gear set destruction within estimated 2–4 weeks.
Solution
Full gearbox disassembly
Gear tooth restoration using welding and precision grinding
Shaft straightening and alignment correction
Housing crack repair and reinforcement
Full reassembly with new bearings and seals
Result
Equipment restored to service — estimated remaining service life 3–5 years
Avoided full unit replacement — estimated saving: significant, as equivalent unit not available domestically
12 days for full repair vs. estimated 60–90 days for imported replacement procurement
Project 4:
Kiln Drive Gearbox Overhaul
Application:
Rotary kiln drive — cement plant, Central Uzbekistan
Equipment:
Heavy-duty open gear reducer (Flender-type unit)
Problem
Increasing gear backlash and elevated noise level over 3-month period
Oil contamination — metallic particles detected in routine oil sample
Production management concerned about kiln stop risk
Engineering Diagnosis
Oil particle analysis indicated secondary gear stage wear. Backlash measurement: 1.8mm — above the 0.8mm limit for this application. Main pinion showed pitting on 40% of tooth contact surface.
Solution
Gear inspection and refurbishment of contact surfaces
Full bearing replacement — both main stages
Lubrication system clean-out and reconfiguration
Pinion replacement from stock
Reassembly and load testing
Result
Backlash corrected to 0.6mm — within specification
Kiln operating without interruption for 14+ months post-repair
Oil sample metallic particle count reduced to baseline level
Scheduled overhaul interval established — annual inspection program agreed with client
Project 5:
Raw Mill Drive Power Optimization
Application:
Raw material grinding mill — cement production
Equipment:
Gearbox + electric motor (SEW-Eurodrive motor-reducer unit)
Problem
Excessive energy consumption — 18% above design specification
Load imbalance between mill compartments
Motor operating at elevated temperature
Engineering Diagnosis
Motor current logging over 72 hours confirmed consistent overload pattern correlated with material feed rate. Gearbox internal efficiency loss estimated at 4–6% due to worn bearing preload. Drive configuration suboptimal for actual material density profile.
Solution
Gearbox bearing replacement and preload adjustment
Motor and gearbox operational matching — control parameters revised
Feed rate optimization recommendations provided to process team
Result
Energy consumption reduced by approximately 14% within 30 days
Motor temperature reduced by 12°C under standard load
Drive efficiency confirmed by power factor measurement before/after
Coupling failure every 6–8 weeks due to shaft misalignment
Vibration transmitted to reactor structure
Engineering Diagnosis
Shaft alignment measurement: 0.7mm parallel offset — significantly exceeding the 0.1mm tolerance required for this coupling type at operating speed. Original coupling selection was rigid type — inappropriate for this drive configuration.
Solution
Replacement of rigid coupling with flexible jaw-type coupling
Precision shaft alignment using dial gauge method
Motor-reducer selection review — confirmed unit was correctly sized
Vibration isolation pad installation at motor mount
Result
Coupling service life increased from 6–8 weeks to 18+ months (last recorded before end of contract period)
Vibration at reactor structure reduced by measured 60%
Project 7:
Pump Station Drive Modernizatio
Application:
Industrial fluid transfer pump station
Equipment:
Electric motor + gearbox + coupling
Problem
High vibration — vibration levels at 3× OEM alarm threshold
Coupling failure every 4–6 weeks
Motor overheating under peak flow conditions
Engineering Diagnosis
Vibration spectrum analysis identified dominant frequency corresponding to 1× shaft speed — classic unbalance signature. Secondary peak at bearing pass frequency indicated bearing damage. Motor current analysis showed intermittent overload during pump cavitation events.
Solution
Dynamic balancing of pump impeller
Bearing replacement and shaft realignment
Coupling upgrade to accommodate angular and parallel misalignment
Motor protection threshold recalibration
Result
Vibration reduced from 3× to within OEM specification
Coupling replacement interval extended to 12+ months
No motor trips recorded in 6 months following repair
Project 8:
Pump Drive System Repair — Water Infrastructure
Application:
Municipal water supply pump station — Central Asia region
Equipment:
Large-frame electric motor (Siemens SIMOTICS-type unit) + gearbox
Problem
Motor insulation degradation — insulation resistance below acceptable level
Gearbox oil leakage — seal failure across multiple positions
Vibration increase over 8-month period
Engineering Diagnosis
Motor insulation testing: 2.4 MΩ at 500V — below the 10 MΩ minimum for this motor class. Gearbox seal failure traced to incorrect seal material for operating temperature range. Vibration source: bearing inner race fretting on output shaft.
Solution
Motor winding insulation restoration — vacuum impregnation process
All gearbox seals replaced — correct material grade specified
Output shaft bearing replacement and housing bore correction
System alignment verification
Result
Motor insulation resistance restored to 480 MΩ — fully operational
Gearbox oil leakage eliminated — zero leakage at 6-month inspection
Vibration at OEM baseline level
Pump station restored to full operational capacity
Project 9:
Conveyor Drive Upgrade — Food Processing
Application:
Product transport conveyor — food processing facility
Equipment:
Motor-reducers (3 units on single line)
Problem
Inconsistent conveyor speed across line — synchronization issue
High wear rate on drive components — replacement every 3 months
Noise level above acceptable for food environment
Engineering Diagnosis
Speed variation traced to inconsistent gear ratios across three motor-reducer units — units were from different production batches with 3.2% speed tolerance mismatch. Wear rate caused by repeated micro-shock loading from speed differential.
Solution
Replacement with matched set of NORD motor-reducers — verified same gear ratio across all three units
Hygienic design units selected — appropriate for food environment
Drive integration into existing conveyor frame without structural modification
Drive component replacement interval extended from 3 months to 18+ months (manufacturer specification: 24 months)
Noise level reduced by 8 dB
What These Projects Demonstrate
Engineering Diagnosis First
Each project begins with actual measurement and analysis — not assumption. Root cause is identified before solution is proposed. This prevents repeat failures.
Repair as a Strategic Option
In 6 of 9 projects above, repair or refurbishment was the optimal solution — faster, significantly cheaper, and equally or more reliable than replacement. We quantify this for clients before work begins.
Multi-Brand Repair Capability
Projects above involved equipment originally produced by Flender, SEW-Eurodrive, Siemens, Wikov, David Brown Santasalo and Soviet-era manufacturers. We work with all of these — as an independent service company.
Local Execution Advantage
Average repair turnaround in these projects: 7–14 days on-site + workshop time. Equivalent foreign service center turnaround for the same equipment: 6–14 weeks, plus logistics.